Resumen Objetivo Establecer la medición ecográfica del diámetro de la vena cava inferior como factor predictor del shock en pacientes politraumatizados. Materiales y Método Estudio de corte transversal donde se determinó la medición ecográfica de la vena cava inferior a 40 pacientes que ingresaron a la Unidad de Politraumatizados (UPT) del Hospital General del Este "Dr. Domingo Luciani", en el período entre enero y abril de 2018. Se seleccionaron 2 grupos; el grupo 1: pacientes en shock , aquellos con tensión arterial sistólica menor a 90 mm Hg al ingreso, y el grupo 2: pacientes controles que mantuvieron cifras tensionales normales. El estudio de imagen de la vena cava inferior se realizó con el equipo de ecografía ALOKA prosound SSD-a5 y con el ultrasonido portátil MicroMaxx SonoSite , en el cual se midió el índice de colapsabilidad. Los hallazgos se registraron en la hoja de recolección de datos. El análisis estadístico se hizo con la prueba de t de student para muestras independientes y la valoración de puntos de corte diagnóstico se hizo con la prueba de ROC. Resultados La media del Índice de colapsabilidad (IC) de la VCI para el grupo control y de shock fue de 26 ± 12,7% y de 58,5 ± 5,9%, respectivamente; El índice de colapsabilidad fue > 50% en todos los pacientes del grupo de shock . Conclusiones La medición del diámetro de la VCI es un predictor de shock , siendo el IC el parámetro más sensible y específico.


Aim To establish the sonographic measurement of the diameter of the inferior vena cava as a predictor of shock in trauma patients. Materials and Method A cross-sectional study to determined the sonographic measurement of the inferior vena cava to 40 patients attended at Hospital Domingo Luciani trauma unit, in the period between January and April of 2018. Two groups were selected; group 1: shock patients, those with systolic blood pressure lower than 90 mm Hg, and the group 2: control patients that kept normal blood pressure. The image study of the inferior vena cava was carried out with the ALOKA prosound ultrasound equipment SSD a5 and with the portable ultrasound MicroMaxx SonoSite, in which the collapsibility index was measured. The findings were recorded in the data collection sheet. The statistical analysis proposed for the comparison of averages was made with the student's t-test for independent samples and the assessment of diagnostic cut-off points was made with a ROC curve. Results the mean of collapsability index of de IVC for control and shock group were 26 ± 12,7% and 58,5 ± 5,9%, respectively; The collapsability index (CI) was > 50% in all patients of shock group. Conclusions The measurement of the ICV diameter is a predictor of shock, being the IC the most sensitive and specific parameter.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Vena Cava, Inferior/diagnostic imaging , Wounds and Injuries/physiopathology , Hypovolemia/diagnostic imaging , Shock/therapy , Wounds and Injuries/surgery , Wounds and Injuries/therapy , Cross-Sectional Studies , Ultrasonography , Arterial Pressure , Fluid Therapy/methods
SELECTION OF CITATIONS
SEARCH DETAIL